Top Quality Systems and Solutions for the Marine World

[ Products ] [ Support ] [ Library ] [ Relax ]

[Manufacturers] [RFQ]

 

Water Quality Monitor (Temperature, Conductivity, Pressure, Dissolved Oxygen, Chlorophyll α and Turbidity)

bulletWQM
Accurate data, unattended
WET Labs and Sea-Bird Electronics have teamed to bring offshore research-grade measurement technology to inshore and estuarine research and ocean observing applications.
The WQM's sensors have the accuracy and precision to track subtle long-term changes in clean ocean environments. By combining multiple active and passive anti-fouling features, the WQM assures this data quality in coastal and inshore regimes. Extensively tested, field trials have demonstrated the WQM's unprecedented long-term stability in biologically rich coastal waters
.
Built for extended deployment
Biofouling and sediment loads are the dominant factors that degrade and limit the data quality from the WQM's sensors, not their inherent stability. These factors can overwhelm inadequately protected sensors and invalidate their data—often in just a few days. The WQM employs active flow control, passive flow prevention, light-blocking, active biocide injection and passive inhibitors to effectively and safely combat internal and external fouling. With fouling minimized, the superior inherent stability of the WQM sensors translates directly to superior long-term data quality.
Cost effective—now and later
The cost of monitoring is tied to the instrument life cycle and real value is ultimately provided only through quality data, day after day, month after month, year after year. The WQM provides quality data while dramatically reducing the need for field and factory service. The bottom line: the WQM delivers unequalled long-term data quality and minimizes operational and maintenance costs.
bullet

Brochure - Hardware User Guide - Software User Guide - Software

Cycle PO4 Sensor

bulletCycle PO4 Sensor
Designed for unattended long-term moored operations, the Cycle-PO4 is the first of WET Labs' line of single analyte chemical sensors.
The Cycle line combines precision micro-fluidics with state-of-the-art optics to provide unparalleled precision and accuracy in operational in-situ monitoring of nutrients.
The Cycle-PO4 features:
- On-board calibration assures quality data.
- Reagent cartridge technology and a straightforward software interface allows setup in minutes.
- Nanomolar-range measurement resolution.
- Meter control can be autonomous or external.
bullet

Brochure - Hardware User Guide - Software User Guide

Fluorometers

bulletEco Fl
Chlorophyll-a fluorescence serves as a valuable indicator of active phytoplankton biomass and chlorophyll concentrations in waters. This measurement is used for tracking biological variability and abundance in the water column.
Ex/Em: 470/695 nm • Sensitivity: 0.01µg/l • Linearity: 99%R2 • Range: 0.01–125 µg/l
Obtain CDOM fluorescence across a wide range of environments, from mangrove swamps to oligotrophic blue water.

Ex/Em: 370/460 nm • Sensitivity: 0.09 ppb QS • Linearity: 99%R2 • Range: 0.09–500 ppb
The qualities of the ECO line are now available for flow and dye tracing studies. Specify measurement sensitivity when ordering.
Uranine (fluorescein) Ex/Em: 470/530 nm • Sensitivity: 0.07 ppb • Linearity: 99%R2 • Range: 0.07–1200 ppb
Detection of the cyanobacteria fraction of the phytoplankton community is now easier and less expensive with the introduction of the phycoerythrin meter, which allows for detection of red cyanobacteria fluorescence.
Rhodamine (and Phycoerythrin) Ex/Em: 540/570 nm • Sensitivity: 0.01 ppb • Linearity: 99%R2 • Range: 0.01–230 ppb

bullet

Brochure - User Guide - ECOView Software - ECOView User's Guide

bulletWetStar Fluorometer
The WETStar fluorometer provides breakthrough performance for detecting various types of fluorescence. It uses a central axial optical tube to provide efficient signal output.
The meter has a unique flow tube design that lends itself to both pump-through and flow-through operation. It's power input of 7–15 VDC and 0–5 VDC analog output allow it to easily mate with existing CTD packages.
bullet

Brochure - User Guide

Turbidity Meters (ECO Scattering Meters)

bulletEco BB
Single-angle Backscattering Meter
The ECO BB measures scattering at 117 degrees, the angle determined as a minimum convergence point for variations in the volume scattering function (VSF) induced by suspended materials and water itself. As a result, the signal measured by this meter is less determined by the type and size of the materials in the water and is more directly correlated to the concentration of the materials. Conversely, the meter provides unparalleled accuracy for any single-angle measurement in determining the optical backscattering coefficient: an important parameter for remote sensing and in many in-water bio-optical applications.
bullet

Brochure - User Guide

bulletEco BB 2F
Combination Backscattering Meter and Fluorometer
The ECO BB2F meter measures optical backscattering at 117 degrees at both 470 and 700 nm and chlorophyll fluorescence within the same volume.
bullet

Brochure - User Guide

bulletEco Triplet
Three-wavelength Backscattering Meter
Developed under the auspices of the National Oceanographic Partnership Program, the ECO Triplet provides optical backscattering measurements at 470, 532 and 660 nm in its standard configuration. Meters are available with a centroid angle of scattering at 117 degrees.
bullet

Brochure - User Guide

bulletEco VSF
Three angle, Single-wavelength VSF
The ECO VSF measures the optical scattering at three distinct angles: 100, 125, and 150 degrees, thus providing the shape of the Volume Scattering Function (VSF) throughout the backscattering region.
bullet

Brochure - User Guide

bulletEco VSF3
Triple Wavelength, Triple Angle VSF
The ECO VSF3 measures the optical scattering at three distinct angles: 100, 125, and 150 degrees, and at wavelengths of 470, 532, and 650 nm, thus providing the shape of the Volume Scattering Function (VSF) throughout its angular domain.
bullet

Brochure - User Guide

bulletEco BB9
Nine Wavelength Configurable Scattering Meter
The ECO BB-9 can be customized with any of the ECO line of optical configurations. For example, scattering can be measured at seven wavelengths as well as CDOM and chlorophyll fluorescence. Further customization is possible by adding pressure and temperature sensors to provide a stand-alone profiling tool.
bullet

Brochure - User Guide

Fluorometer & Turbidity

bulletEco FLNTU
The ECO FLNTU is a dual-wavelength, single-angle sensor for simultaneously determining both chlorophyll fluorescence and turbidity.
bullet

Brochure - User Guide

Transmissiometers

bulletC-Star
Transmissiometer
The C-Star incorporates a novel monolithic housing with a highly integrated opto-electronic design to provide a low cost, compact solution for underwater measurements of beam transmittance. The instrument is capable of either free space measurements, or through the use of an optical flow tube, flow-through sampling with a pump. It can be used in profiling, moored, or underway applications. C-Star’s analog output allows easy interfacing to a wide variety of small battery-powered CTDs and loggers.
bullet

Brochure - User Guide

bulletC-Rover
Transmissiometer
C-Rover is designed for long-term deployment aboard profiling floats. It's near-neutral buoyancy simplifies ballasting, and it is capable of being "parked" at depth (2000 m). Similar to the C-Star, the Rover is lighter weight; C-Star is more rugged and better suited to ship-based operations.
bullet

Brochure - User Guide

In Situ Spectrophotometers

bullet ac-spectra
In-situ Spectrophotometer
Based on the highly successful ac-9, the ac-spectra (ac-s) offers almost an order of magnitude increase in spectral resolution of in-situ absorption and beam attenuation. The 4 nm resolution allows for spectral "fingerprinting" and deconvolution analysis.
bullet

Brochure - User Guide - Protocol document

bulletac-9
Absorption and Attenuation Meter
The ac-9 simultaneously determines the spectral transmittance and spectral absorption of water over nine wavelengths. The unit offers compact size, high precision, and excellent stability in providing a method for determining the absorption and beam attenuation coefficients.
bullet

Brochure - User Guide - Protocol document

bulletac-9 plus
Absorption and Attenuation Meter +
The ac-9 Plus combines the power of the standard ac-9 with the added capability of accepting and integrating data from ancillary sensors, which is incorporated into the serial (RS-232) data stream. WETView, our host data collection program, records and displays the data from the ac-9 Plus in real-time. This powerful new tool allows researchers to simultaneously collect the data needed to describe inherent optical property measurements of natural waters for effects such as salinity and temperature with one integrated package. The ac-9 Plus is available in several standard configurations:
blue bullet ac-9 Plus + CTD
blue bullet ac-9 Plus + ECO BB + CTD
blue bullet ac-9 Plus + CTD + ECO BB3.
It supports many popular CTDs including the SBE 19, 25, and 37, as well as CTDs from other manufacturers. Upgrades are available for existing ac-9 sensors.
bullet

Brochure - User Guide - Protocol document


Top of Page

 

Via del Monte 1080 - 47521 Cesena (FC) Italy - Tel +39 0547 64 65 61 - Fax +39 0547 300 877 
P.I. 02253520403 - Cap.Soc. €26.000 i.v. - Reg. Imprese: 19207 - Reg. R.E.A. Forlì-Cesena 251620 - Codice Anagrafe Nazionale Ricerche: 53253XXV
Copyright © 1993-2012 Communication Technology srl - Last modified: 18-lug-2012