Manufacturers ] [
Applications ]
[ RFQ ] [ Rentals ]


DCR - Doppler Current Recorder
The DCR – Doppler Current Recorder is a rugged,
true vector averaging sensor for measuring current speed and direction in water
that employs the same transducer head used in Aanderaa’s RCM-9 current
meters, but adding ease of use and improved capabilities
& versatility to the system.
The DCR
can record data also from the best available sensors from the best manufacturers
in the world for each specific application. When you need to measure parameters
in your moving water with the highest possible quality and reliability, the
DCR is the solution.

|
|
| |
Rugged,
Small Size |
| |
High
Accuracy |
| |
Insensitive
to fouling |
Improvements
|
| Setup |
Easy & User-friendly RS-232
commands |
| Data Download |
Easy & User-friendly RS-232
serial data output, no special memory reader needed |
| Data format |
NMEA-style
ASCII files |
| Memory |
Huge
internal non-volatile memory card with capacity up
to 512 MB |
|
Configuration |
The transducer
head can be oriented
downward to make measures close to the bottom |
| Aux Sensors |
The DCR can interface the best
available sensors of the best manufacturers |
Standard Configuration
|
| Housing |
Black Delrin
housing, 200 m depth rated |
| Sensors |
Aanderaa
DCS-3900R Doppler Current and Temperature Sensor |
| Aux Input |
16 bit, 8 single ended or 4
differential auxiliary analog sensor input channels |
| |
1 RS-232 digital sensor input
channel |
| Memory |
128 MB
internal non-volatile memory card |
| Software |
OceanPro
Light for instrument setup, data download & display |
|
|
| Housing |
AISI 316 Stainless Steel housing, 500 m depth rated |
| Memory |
256 MB
or 512 MB internal non-volatile memory card |
| Aux Input |
4 additional RS-232 digital
sensor input channel |
|
Aux Sensors |
SeaBird
SBE-37SI MicroCAT
with SBE 5T pump (uses 1 RS-232 channel) |
| |
SeaBird
SBE 18 pH Sensor
(uses 1 analog channel) |
| |
SeaBird
SBE 27 pH/ORP Sensor (uses
2 analog channels) |
| |
SeaBird
SBE 43 Dissolved Oxygen Sensor
(uses 1 analog channel) |
| |
Turner Designs SCUFA Underwater Fluorometer
(uses 1 RS-232 channel) |
| |
Turner Designs SCUFA Underwater Fluorometer &
turbidimeter
(uses 1 RS-232 channel) |
| |
Biospherical QSP-2100 Scalar PAR
(uses 1 RS-232 channel) |
| |
Biospherical QSP-2200
Scalar PAR with analog signal output
(uses 1 analog channel) |
| |
Biospherical QCP-2100
Cosine PAR with RS-232 signal output
(uses 1 RS-232 channel) |
| |
Biospherical QCP-2300 Cosine PAR with log analog signal output
(uses 1 analog channel) |
|
|
D&A OBS-3A
Particle Monitor (uses 1 RS-232 channel) |
|
|
Seapoint Turbidity Meter
(uses 1 analog channel) |
|
|
Sequoia LISST-25 Laser
Scatterometer (uses 1 RS-232 channel) |
| Software |
OceanPro
Oceanographic SQL Database |
Specifications
|
Measurement Range
|
|
|
|
|
Curr. Direction |
0 - 360° magnetic |
|
Temperature |
-10 to 43°C |
Accuracy
|
|
|
± 0.15 cm/s or ± 1% of reading,
whichever is the gratest |
|
Curr. Direction |
± 5° for 0-15° tilt, ±7.5° for
15-35° tilt |
|
Temperature |
± 0.08°C at 10 pings per second,
better than ± 0.16°C at 1 ping per second |
Resolution
|
|
|
0.1% of FSR (0.3 cm/s) |
|
Curr. Direction |
0.35° |
|
Temperature |
0.05 °C |
The best available
quality for each measured parameter
A DCR with
auxiliary sensors combines all the instruments you might want to deploy in one
single instrument. Data are always perfectly synchronized and are stored in one
single memory.
In one single piece of
equipment you can have RCM9-quality data for single point currents, SeaBird-quality
data for CTD, pH, ORP & DO, Turner-quality data for fluorescence,
Sequoia-quality data for suspended particles, and so on.
"Happy Scientist" Configuration Example
|
|
Parameters |
Current
Speed and Direction, Temperature, Conductivity, Salinity, Density, pH,
Redox, Dissolved Oxygen, Fluorescence, Upward PAR, Downward PAR,
Suspended Particle
Total Volume & Total Area, Sauter Mean Diameter, Optical Back Scatter |
| |
|
| Sensors |
Aanderaa
DCS-3900R Doppler Current and Temperature Sensor |
| |
SeaBird
SBE-37SI MicroCAT
with SBE 5T pump (uses 1° RS-232 channel) |
| |
Turner Designs SCUFA Underwater Fluorometer
(uses 2° RS-232 channel) |
| |
Sequoia LISST-25 Laser
Scatterometer (uses 3° RS-232 channel) |
| |
D&A OBS-3A
Particle Monitor (uses 4° RS-232 channel) |
| |
SeaBird
SBE 27 pH/Redox Sensor (uses
1° and 2° analog channels) |
| |
SeaBird
SBE 43 Dissolved Oxygen Sensor
(uses 3° analog channel) |
| |
Biospherical QCP-2300 Upward
Cosine PAR
(uses 4° analog channel) |
| |
Biospherical QCP-2300 Downward
Cosine PAR
(uses 5° analog channel) |
Top of Page |