|

[ Tech Papers ] [
Tutorials ] [
App Notes ]
[ References ]
[ RDI ] [ SeaBird ] [ Turner ] [ Sequoia ]

SBE by
Application
SBE by
model number
SBE
Application Notes
|
Note # |
Title and Revision Date |
Link |
Applies to |
|
2D |
Instructions for Care and Cleaning of
Conductivity Cells (10/06) |
pdf |
SBE
4,
9plus,
16, 16plus,
16plus-IM,
19, 19plus,
21,
25, 26,
26plus,
37 (IM,
IMP,
SM,
SMP,
SI,
SIP),
45,
49,
52-MP,
53 |
| 6 |
Determination of Sound Velocity from CTD Data (08/04) |
pdf |
SBE
4,
9plus,
16, 16plus,
16plus-IM,
19, 19plus,
21,
25, 26,
26plus,
37 (IM,
IMP,
SM,
SMP,
SI,
SIP),
45,
49,
52-MP,
53 |
| 7 |
Calculation of Calibration Coefficients for Transmissometers (03/04) |
pdf |
--- |
| 8 |
Sea-Bird Universal Opto-isolated Junction Box (03/01) |
pdf |
SBE
16, 19, 20,
21, 26 |
| 9 |
Calculating Calibration Coefficients for Sea Tech Fluorometer and WETLabs
Flash Lamp Fluorometer (FLF) (08/01) |
pdf |
--- |
| 10 |
Compressibility Compensation of Sea-Bird Conductivity Sensors (07/05) |
pdf |
SBE
4,
9plus,
16, 16plus,
16plus-IM,
19, 19plus,
21,
25, 26,
26plus,
37 (IM,
IMP,
SM,
SMP,
SI,
SIP),
45,
49,
52-MP,
53 |
| 11
General |
PAR
Light Sensors (05/07) |
pdf |
--- |
| 11
Chelsea |
Calculating Calibration Coefficients for Chelsea PAR Light Sensor with
Built-In Log Amplifier
(05/07) |
pdf |
--- |
| 11
Licor |
Calculating Calibration Coefficients for Licor Underwater Type SA PAR Light
Sensor without Built-In Log Amplifier (05/07) |
pdf |
--- |
| 11 QSP-L |
Calculating Calibration Coefficients for Biospherical PAR Sensor with
Built-In Log Amplifier (05/07) |
pdf |
--- |
| 11 QSP-PD |
Calculating Calibration Coefficients for Biospherical PAR Sensor without
Built-In Log Amplifier (05/07) |
pdf |
--- |
| 11 S |
Using
Biospherical Surface PAR Light Sensor with SBE 11plus Deck Unit
(05/07) |
pdf |
Biospherical PAR with SBE
911plus |
| 12-1 |
Pressure Port Oil Refill Procedure and Nylon Capillary Fitting Replacement
(01/04) |
pdf |
SBE
9plus,
16, 19, 25,
29 |
| 13-1 |
SBE
13, 23, & 30 Dissolved Oxygen Sensor Calibration (OXFIT version 2.1) (05/07) |
pdf |
SBE
13B, 13Y, 23B, 23Y, 30 |
| 13-2 |
Dissolved Oxygen Sensor Disassembly & Reassembly Instructions (06/94) |
pdf |
SBE
13B, 23B |
| 13-3 |
SBE
Dissolved Oxygen Sensor Calibration Note (new value for the Pcor
coefficient) (03/01) |
pdf |
SBE
13B, 23B |
| 13-4 |
SBE
13, 23, & 30 Dissolved Oxygen Sensor Life Expectancy (03/01) |
pdf |
SBE
13B, 23B, 30 |
| 13-5 |
Modifying the SBE 13 Oxygen Sensor for 5 Volt Output (05/07) |
pdf |
SBE
13 |
| 14 |
1978
Practical Salinity Scale (01/89) |
pdf |
SBE
9plus,
16, 16plus,
16plus-IM,
19, 19plus,
21,
25, 26,
26plus,
37 (IM,
IMP,
SM,
SMP,
SI,
SIP),
45,
49,
52-MP,
53 |
| 15 |
TC
Duct Assembly & Plumbing Installation (09/03) |
pdf |
SBE
9plus,
25 |
| 16 |
Entering Calibration Coefficients for D&A Instruments OBS-3 Optical
Backscatter Sensor (05/07) |
pdf |
--- |
| 17 |
Instructions for Use of the SBE 14 Remote Depth Readout (05/07) |
pdf |
SBE
14 |
| 18-1 |
SBE
18, 27, and 30 and AMT pH Sensor Calibration (PHFIT version 2.0) (03/05) |
pdf |
SBE
18,
27, 30,
and AMT |
| 18-2 |
SBE
18, 22, 27, and 30 pH Sensor Storage, Maintenance, and Calibration (05/07) |
pdf |
SBE
18,
22, 27,
and 30 |
| 18-3 |
SBE 18
pH Sensor Hook-up Instructions (07/01) |
pdf |
SBE
18 |
| 18-4 |
SBE 18
pH Sensor Calibration Equation Error (08/94) |
pdf |
SBE
18 |
| 19 |
SBE 27
or 30 Oxygen Reduction Potential ORP Sensor (05/07) |
pdf |
SBE
27, 30 |
| 20 |
Re-calibration of Paroscientific Digiquartz Pressure Sensors (06/89) |
pdf |
SBE
12 |
| 21 |
Instructions for Use of Ni-Cad Battery Packs (07/04) |
htm or
pdf |
SBE
17plus,
19, 19plus,
25 |
| 22 |
Pump
Speed Adjustment Instructions (03/91) |
pdf |
SBE
5 (old) |
| 27Druck |
Strain
Gauge Pressure Sensor Error Sources (07/05) -- current production
instruments with Druck pressure sensors |
pdf |
SBE
16plus,
16plus-IM,
19plus,
25,
26plus,
29, 37
(IM,
IMP,
SM,
SMP,
SI,
SIP),
39,
39-IM,
49,
50,
52-MP |
| 27 |
Strain
Gauge Pressure Sensor Error Sources (05/07) -- older instruments
with Paine pressure sensors |
pdf |
SBE
16, 19, 25,
29, 37
(IM,
SM,
SI),
39 |
| 29 |
Configuring the SBE 19 (not 19plus) SEACAT Profiler with Options and
Auxiliary Sensors (03/01) |
pdf |
SBE
19 |
| 30 |
Fresh
Water Conductivity Measurements using the SBE 19 (not 19plus) SEACAT
Profiler (03/01) |
pdf |
SBE
19 |
| 31 |
Computing Temperature and Conductivity Slope and Offset
Correction Coefficients from Laboratory Calibrations and Salinity Bottle
Samples (07/07) |
pdf |
--- |
| 32 |
Dissolved Oxygen Sensors Using the YSI 5739 Oxygen Probe (05/97) |
pdf |
SBE
13Y, 23Y |
| 33 |
Using
the DC Opto Isolated Junction Box (03/01) |
pdf |
PN
91118 |
| 34 |
Instructions for Use of Conductivity Cell Filling and Storage Device PN
50087 and 50087.1 (01/05) |
pdf |
SBE
9plus,
16, 16plus,
16plus-IM,
19, 19plus,
25,
49 |
| 35 |
Use of
SBE 911plus with General Oceanics 1015 Rosette® (02/92) |
pdf |
SBE
911plus |
| 36a |
Installation of P/N 50094 Conductivity Cell Tubing Connector Kit (04/98) |
pdf |
SBE
4C,
9plus,
25 |
| 38 |
TC
Duct Fundamentals (12/92) |
pdf |
SBE
9plus,
25 |
| 39 |
Calculating Calibration Coefficients for the Chelsea Aquatracka Fluorometer
(05/07) |
pdf |
--- |
| 40 |
SBE 5T
and 5P Pump Speed Adjustment Instructions (06/07) |
pdf |
SBE
5T and 5P |
| 41 |
Calculating Calibration Coefficients for the WET Labs WETStar Fluorometer
(05/07) |
pdf |
--- |
| 42 |
ITS-90
Temperature Scale (05/07) |
pdf |
SBE
3plus,
3F,
3S,
9plus,
16, 16plus,
16plus-IM,
19, 19plus,
25, 26,
26plus,
35,
35RT,
37 (IM,
IMP,
SM,
SMP,
SI,
SIP),
38,
39,
39-IM,
45,
49,
52-MP,
53 |
| 43 |
Universal Ni-Cad Battery Charger Operating Instructions (01/95) |
pdf |
SBE
17plus,
19, 19plus,
25 |
| 45 |
Guide
to SBE 32 Carousel Water Sampler Configuration Options (05/07) |
pdf |
SBE
32 |
| 46 |
DC
Opto-Isolated RS-485 to RS-232 Junction Box P/N 90238 Instructions for
Application and Use (03/01) |
pdf |
P/N
90238 |
| 47 |
Using
Biospherical Surface PAR Light Sensor with SBE 33 or SBE 36 Deck Unit
(05/07) |
pdf |
Biospherical PAR with SBE
33 or
36 |
| 48 |
Entering Calibration Coefficients for the Seapoint Turbidity Meter (05/07) |
pdf |
--- |
| 51 |
Using
a TC Duct on Pumped SBE 19 (not 19plus) SEACATs (03/01) |
pdf |
SBE
19 |
| 52 |
AC
Powered Opto-Isolated RS-485 to RS-232 Junction Box P/N 80491 Instructions
for Application and Use (09/98) |
pdf |
P/N
80491 |
| 53 |
Instructions and use of Bay Model Sensors (01/99) |
pdf |
Bay
Model Thermosalinograph |
| 54 |
Entering Calibration Coefficients for the Seapoint Fluorometer (05/07) |
pdf |
--- |
| 55 |
GPIB
Interface Board FAQs (10/04) |
pdf |
--- |
| 56 |
Interfacing to RS-485 Sensors (09/03) |
pdf |
SBE
16, 16plus,
37 (SI,
SIP,
SM,
SMP),
38 |
| 57 |
Connector Care and Cable Installation (08/07) |
pdf |
All
Instruments |
| 58 |
Sea-Bird DOS-Based Terminal Programs and Microsoft Windows 95/98 (05/04) |
pdf |
All
Instruments |
| 59 |
A
Load-Bearing Underwater Cable for Hand-Hauled, Real-Time Profiling (09/06) |
pdf |
SBE
19, 19plus,
25 |
| 60 |
Year
2000 Compatibility for Sea-Bird Instruments and Software (01/01) |
pdf |
All
Instruments |
| 61 |
Calculating Calibration Coefficients for the Chelsea Minitracka Fluorometer
(02/01) |
pdf |
--- |
| 62 |
Calculating Calibration Coefficients for the WET Labs ECO-AFL or ECO-FL
Fluorometer (05/07) |
pdf |
--- |
| 63 |
Calculating Calibration Coefficients for the Turner SCUFA (I, II, or III)
Fluorometer/OBS (05/07) |
pdf |
--- |
| 64 |
SBE 43
Dissolved Oxygen Sensor -- Background Information, Deployment
Recommendations, and Cleaning and Storage (07/07) |
pdf |
SBE 43 |
| 64-1 |
Plumbing Installation -- SBE 43 DO Sensor and Pump on a CTD (09/03) |
pdf |
SBE
9plus,
19, 19plus,
25,
43 |
| 64-2 |
SBE 43
Dissolved Oxygen Sensor Calibration using Winkler Titrations (08/05) |
pdf |
SBE
43 |
| 65 |
Interfacing Pro-Oceanus Gas Tension Device (GTD) to SBE 16plus SEACAT
-- Information incorporated in SBE 16plus manual (RS-232
or
RS-485) and 16plus V2 manual (RS-232
or RS-485 [not available yet]) |
--- |
--- |
| 66 |
Routine Maintenance for the SBE 32 Carousel Water Sampler (10/07) |
pdf |
SBE
32 |
| 67 |
Editing Sea-Bird .hex Data Files (10/01) |
pdf |
SBE
16, 16plus,
16plus-IM,
19, 19plus,
21,
25,
45,
49 |
| 68 |
Using
USB Ports to Communicate with Sea-Bird Instruments (11/06) |
pdf |
All
RS-232 Instruments |
| 69 |
Conversion of Pressure to Depth (07/02) |
pdf |
SBE
9plus,
16, 16plus,
16plus-IM,
19, 19plus,
25, 26,
26plus,
29, 37
(IM,
IMP,
SM,
SMP,
SI,
SIP),
39,
39-IM,
49,
50,
52-MP,
53 |
| 70 |
Installing Anti-Foulant Device Mount Kit on SBE 4, 16, 19, and 21
Conductivity Cells (10/06) |
pdf |
SBE
4
(moored), 16, 19 (moored mode),
21; and
26, 26plus,
or 53
with optional SBE 4 conductivity sensor |
| 71 |
Desiccant Use and Regeneration (drying) (07/05) |
pdf |
Most
Instruments |
| 72 |
Setting up WET Labs ECO-FL Fluorometer with Bio-Wiper™ (05/05) |
pdf |
--- |
| 73 |
Using
Instruments with Pressure Sensors at Elevations Above Sea Level (07/05) |
pdf |
SBE
9plus,
16plus,
16plus-IM,
19plus,
25,
26plus,
29, 37
(SI,
SIP,
SM,
SMP,
IM,
IMP),
39,
39-IM,
49,
50,
52-MP,
53 |
| 74 |
Calculating Calibration Coefficients for Turner Cyclops-7 Fluorometer
(02/05) |
pdf |
--- |
| 75 |
Maintenance of SBE 5T, 5P, and 5M Pumps (06/07) |
pdf |
SBE
5M,
5P,
5T |
| 76 |
pH or
pH/ORP Sensors and Moored Applications (08/04) |
pdf |
SBE
18,
27 |
| 77 |
Entering Calibration Coefficients for the Seapoint Ultraviolet
Fluorometer (05/07) |
pdf |
--- |
| 78 |
Inductive Modem Module (IMM) Quick Start Instructions (09/05) |
pdf |
IMM |
| 79 |
Configuring Inductive Modem Module (IMM) for Logic Level Serial (LLS)
(09/05) |
pdf |
IMM |
| 80 |
Inductive Modem (IM) Communication between Two Inductive Modem Modules (IMMs)
(09/05) |
pdf |
IMM |
| 81 |
Entering Calibration Coefficients for D & A Instruments OBS-3+ Optical
Backscatter Sensor (05/07) |
pdf |
--- |
| 82 |
Guide
to Specifying a CTD (10/05) |
pdf |
--- |
| 83 |
Deployment of Moored Instruments (04/06) |
pdf |
SBE
16plus,
16plus-IM,
19plus,
26plus,
37 (SI,
SIP,
SM,
SMP,
IM,
IMP),
39,
39-IM,
53 |
| 84 |
Using
Instruments with Druck Pressure Sensors in Muddy or Biologically Productive
Environments (07/06) |
pdf |
SBE
16plus,
16plus-IM,
19plus,
37 (SI,
SIP,
SM,
SMP,
IM,
IMP),
39,
39-IM,
49,
50,
52-MP |
| 85 |
Handling of Ferrite Core on Instruments with Inductive Modem Telemetry
(12/06) |
pdf |
SBE
16plus-IM,
37-IM,
37-IMP,
39-IM,
44,
ICC |
| 86 |
Change
to SBE 9plus CTD Bottom Contact Switch Connector (JB6) (2/07) |
pdf |
SBE
9plus |
| 87 |
Calculating Calibration Coefficients for the Wet Labs ECO-BB Scattering /
Turbidity Meter (05/07) |
pdf |
--- |
|